Eco Green Solar

What’s a Heat Pump ?

The heat pump makes use of a refrigerant for its operaon. The low emperature refrigerant absorbs free heat from the atmospheric air in the evaporator is compressed by a highly efficient electrical compressor to a high- temperature and high-pressure vapor refrigerant. This vapor is then passed through a heat exchanger (condenser) to transfer the heat to the water in the storage tank to produce hot water. The refrigerant then passes through an expansion valve and it goes back to the evaporator for absorbing the free heat from the atmospheric air again and the cycle is repeated.

Features

BENEFITS of ECO GREEN HEAT PUMP

Installation Diagram

Technical Specification

MODELEGHPEGHP-X-10EGHP-X-15EGHP-X-20EGHP-X-25
Heating CapacitykW3.85.57.69.2
Power InputkW0.931.351.892.25
COP (Heating Mode)/4.094.074.084.08
Cooling CapacitykW2.473.584.945.98
Power InputkW0.921.311.822.20
COP (Cooling Mode)/2.682.722.722.72
Line Wiremm211.52.52.5
Rated CurrentA4.76.89.411.4
Max. Running CurrentA6.18.912.214.8
Hot Water VolumeL/Hr102148204247
Power SupplyV220~240V/50Hz/1ph
Compressor QuantityNos.01010101
Compressor Type/RotaryRotaryRotaryRotary
Compressor Brand/Mitsubishi / Highly /GMCC / Panasonic
Expansion Method/ElectronicExpansion Valve
Circulation Water PumpWILORS15-6RS15-6RS15-6RS15-6
NoisedB42424545
Water Pipe ConnectionInch0.750.750.750.75
Fan Motor PowerW30304040
Fan Motor QuantityNos.01010101
Refrigerant/R417aR417aR417aR417a
Level of Protection/IPX4IPX4IPX4IPX4
Condenser/Highefficiency tube in shellheat exchanger (coppertube)
Evaporator/Hydrophilicaluminum foil and innergrooved copper tube heatexchanger
Working Mode/Heating/ Cooling / FastHeating / High Temperature
Cabinet/Galvanized sheet withepoxy spray coat
Dimentionsmm970x300x550970x300x5501006x350x6181006x350x618
Net WeightKg42505463
  • Rated working condition: Cooling: source side inlet/outlet water temp: 30°C/35°C, load side inlet/outlet water temp: 12°C/7°C; Heating: source side inlet/outlet water temp: 15°C/10°C, load side inlet/outlet water temp: 40°C/45°C.